YIC-IR

浏览/检索结果: 共9条,第1-9条 帮助

限定条件                        
已选(0)清除 条数/页:   排序方式:
In situ electrochemical synthesis of graphene-poly(arginine) composite for p-nitrophenol monitoring 期刊论文
JOURNAL OF HAZARDOUS MATERIALS, 2022, 卷号: 421, 页码: 11
作者:  Li, Yiwei;  Ma, Yaohong;  Lichtfouse, Eric;  Song, Jin;  Gong, Rui;  Zhang, Jinheng;  Wang, Shuo;  Xiao, Leilei
浏览  |  Adobe PDF(8256Kb)  |  收藏  |  浏览/下载:873/302  |  提交时间:2021/11/09
P-nitrophenol  Graphene  Poly-arginine  Electrochemical analysis  Wastewater monitoring  
Self-Sterilizing Polymeric Membrane Sensors Based on 6-Chloroindole Release for Prevention of Marine Biofouling 期刊论文
ANALYTICAL CHEMISTRY, 2020, 卷号: 92, 期号: 18, 页码: 12132-12136
作者:  Jiang, Tianjia;  Qi, Longbin;  Hou, Chao;  Fang, Shengtao;  Qin, Wei
浏览  |  Adobe PDF(1689Kb)  |  收藏  |  浏览/下载:540/215  |  提交时间:2021/06/16
In Vivo Molecular Insights into Syntrophic Geobacter Aggregates 期刊论文
ANALYTICAL CHEMISTRY, 2020, 卷号: 92, 期号: 15, 页码: 10402-10411
作者:  Wei, Wenchao;  Plymale, Andrew;  Zhu, Zihua;  Ma, Xiang;  Liu, Fanghua;  Yu, Xiao-Ying
Adobe PDF(1253Kb)  |  收藏  |  浏览/下载:381/52  |  提交时间:2021/06/21
Fluorescence detection of 2,4-dichlorophenoxyacetic acid by ratiometric fluorescence imaging on paper-based microfluidic chips 期刊论文
ANALYST, 2020, 卷号: 145, 期号: 3, 页码: 963-974
作者:  Zhang, Zhong;  Ma, Xin;  Li, Bowei;  Zhao, Jia;  Qi, Ji;  Hao, Guoying;  Rong Jianhui;  Yang, Xingbin
Adobe PDF(4979Kb)  |  收藏  |  浏览/下载:486/139  |  提交时间:2020/07/08
MOLECULARLY IMPRINTED POLYMER  SOLID-PHASE EXTRACTION  QUANTUM DOTS  LIQUID-CHROMATOGRAPHY  SENSOR  VEGETABLES  FRUITS  
Low pH in simulated acid rain promotes the toxicity of copper on the physiological performance in Sargassum horneri 期刊论文
PHOTOSYNTHETICA, 2020, 卷号: 58, 期号: 3, 页码: 853-861
作者:  Zhong, Z. H.;  Qin, S.;  Wang, Y.;  Ma, C.;  Liu, Z. Y.
Adobe PDF(1452Kb)  |  收藏  |  浏览/下载:353/21  |  提交时间:2021/06/21
environmental problem  metal pollution  photoprotective ability  photosynthetic apparatus  Sargassum beds  
Glucose biosensor using fluorescence quenching with chitosan-modified graphene oxide 期刊论文
MICRO & NANO LETTERS, 2019, 卷号: 14, 期号: 3, 页码: 344-348
作者:  Li, WJ;  Jiang, TT;  Pu, Y;  Jiao, XD;  Tan, WQ;  Qin, S
Adobe PDF(1618Kb)  |  收藏  |  浏览/下载:403/92  |  提交时间:2020/07/08
biochemistry  biosensors  nanosensors  nanofabrication  fluorescence  molecular biophysics  radiation quenching  chemical sensors  sugar  proteins  biomedical optical imaging  graphene compounds  GO-CS  low concentrations  competitive binding  maltose-binding protein  recombinant phycocyanin  far-red fluorescence  MBP-rPC  rPC emission  rPC fluorescence  linear detection range  glucose biosensor  fluorescence quenching  chitosan-modified graphene oxide  low-molecular-weight chitosan  glucose detection  fluorescence resonance energy transfer  graphene oxide nanomaterial  mass 0  1 mg to 1  0 mg  CO  
Biosynthesis of au nanoparticles by a marine bacterium and enhancing their catalytic activity through metal ions and metal oxides 期刊论文
BIOTECHNOLOGY PROGRESS, 2019, 卷号: 35, 期号: 2, 页码: UNSP e2727
作者:  Zhang, HK;  Hu, XK
Adobe PDF(833Kb)  |  收藏  |  浏览/下载:306/90  |  提交时间:2020/07/08
biosynthesis  marine bacterium  catalytic reduction  metal ions  metal oxides  
Biosynthesis of Pd and Au as nanoparticles by a marine bacterium Bacillus sp GP and their enhanced catalytic performance using metal oxides for 4-nitrophenol reduction 期刊论文
ENZYME AND MICROBIAL TECHNOLOGY, 2018, 卷号: 113, 页码: 59-66
作者:  Zhang, HK;  Hu, XK
Adobe PDF(875Kb)  |  收藏  |  浏览/下载:318/95  |  提交时间:2020/07/08
Marine bacterium  Pd(II)  Au(III)  Catalytic reduction  Metal oxides  
Functionalized polypyrrole nanotube arrays as electrochemical biosensor for the determination of copper ions 期刊论文
ANALYTICA CHIMICA ACTA, 2012, 卷号: 746, 期号: ., 页码: 63-69
作者:  Lin, Meng;  Hu, Xiaoke;  Ma, Zhaohu;  Chen, Lingxin
浏览  |  Adobe PDF(968Kb)  |  收藏  |  浏览/下载:1487/481  |  提交时间:2013/03/08
Electrochemical Biosensor  Conducting Polymer  Polypyrrole Nanotube Arrays  Zinc Oxide Nanowire Arrays  Copper Ions