A Potentiometric Flow Biosensor Based on Ammonia-Oxidizing Bacteria for the Detection of Toxicity in Water
Zhang, Qianyu1,2; Ding, Jiawang1; Kou, Lijuan1,2; Qin, Wei1; Qin, W (reprint author), Chinese Acad Sci, Yantai Inst Coastal Zone Res YIC,YICCAS, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai 264003, Peoples R China. qyzhang@yic.ac.cn; jwding@yic.ac.cn; ljkou@yic.ac.cn; wqin@yic.ac.cn
发表期刊SENSORS
ISSN1424-8220
2013-06-01
卷号13期号:6页码:6936-6945
关键词Potentiometry Flow Biosensors Ion-selective Electrodes Toxicity Nitrosomonas Europaea
产权排序[Zhang, Qianyu; Ding, Jiawang; Kou, Lijuan; Qin, Wei] Chinese Acad Sci, Yantai Inst Coastal Zone Res YIC,YICCAS, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai 264003, Peoples R China; [Zhang, Qianyu; Kou, Lijuan] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
英文摘要A flow biosensor for the detection of toxicity in water using the ammonia-oxidizing bacterium (AOB) Nitrosomonas europaea as a bioreceptor and a polymeric membrane ammonium-selective electrode as a transducer is described. The system is based on the inhibition effects of toxicants on the activity of AOB, which can be evaluated by measuring the ammonium consumption rates with the ammonium-selective membrane electrode. The AOB cells are immobilized on polyethersulfone membranes packed in a holder, while the membrane electrode is placed downstream in the flow cell. Two specific inhibitors of the ammonia oxidation. allylthiourea and thioacetamide. have been tested. The IC50 values defined as the concentration of an inhibitor causing a 50% reduction in the ammonia oxidation activity have been measured as 0.17 mu M and 0.46 mu M for allylthiourea and thioacetamide, respectively. The proposed sensor offers advantages of simplicity, speed and high sensitivity for measuring toxicity in water.; A flow biosensor for the detection of toxicity in water using the ammonia-oxidizing bacterium (AOB) Nitrosomonas europaea as a bioreceptor and a polymeric membrane ammonium-selective electrode as a transducer is described. The system is based on the inhibition effects of toxicants on the activity of AOB, which can be evaluated by measuring the ammonium consumption rates with the ammonium-selective membrane electrode. The AOB cells are immobilized on polyethersulfone membranes packed in a holder, while the membrane electrode is placed downstream in the flow cell. Two specific inhibitors of the ammonia oxidation. allylthiourea and thioacetamide. have been tested. The IC50 values defined as the concentration of an inhibitor causing a 50% reduction in the ammonia oxidation activity have been measured as 0.17 mu M and 0.46 mu M for allylthiourea and thioacetamide, respectively. The proposed sensor offers advantages of simplicity, speed and high sensitivity for measuring toxicity in water.
文章类型Article
资助机构Instrument Developing Project of the Chinese Academy of Sciences [YZ201161]; National Natural Science Foundation of China [41176081, 21207156]; Taishan Scholar Program of Shandong Province [TS20081159]
收录类别SCI
语种英语
关键词[WOS]NITROSOMONAS-EUROPAEA ; NITRIFICATION ; INHIBITORS ; BIOASSAY
研究领域[WOS]Chemistry ; Electrochemistry ; Instruments & Instrumentation
WOS记录号WOS:000320767600004
引用统计
被引频次:16[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.yic.ac.cn/handle/133337/6986
专题中国科学院海岸带环境过程与生态修复重点实验室
通讯作者Qin, W (reprint author), Chinese Acad Sci, Yantai Inst Coastal Zone Res YIC,YICCAS, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai 264003, Peoples R China. qyzhang@yic.ac.cn; jwding@yic.ac.cn; ljkou@yic.ac.cn; wqin@yic.ac.cn
作者单位1.Chinese Acad Sci, Yantai Inst Coastal Zone Res YIC,YICCAS, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai 264003, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Zhang, Qianyu,Ding, Jiawang,Kou, Lijuan,et al. A Potentiometric Flow Biosensor Based on Ammonia-Oxidizing Bacteria for the Detection of Toxicity in Water[J]. SENSORS,2013,13(6):6936-6945.
APA Zhang, Qianyu.,Ding, Jiawang.,Kou, Lijuan.,Qin, Wei.,Qin, W .,...&wqin@yic.ac.cn.(2013).A Potentiometric Flow Biosensor Based on Ammonia-Oxidizing Bacteria for the Detection of Toxicity in Water.SENSORS,13(6),6936-6945.
MLA Zhang, Qianyu,et al."A Potentiometric Flow Biosensor Based on Ammonia-Oxidizing Bacteria for the Detection of Toxicity in Water".SENSORS 13.6(2013):6936-6945.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
A Potentiometric Flo(597KB) 开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang, Qianyu]的文章
[Ding, Jiawang]的文章
[Kou, Lijuan]的文章
百度学术
百度学术中相似的文章
[Zhang, Qianyu]的文章
[Ding, Jiawang]的文章
[Kou, Lijuan]的文章
必应学术
必应学术中相似的文章
[Zhang, Qianyu]的文章
[Ding, Jiawang]的文章
[Kou, Lijuan]的文章
相关权益政策
暂无数据
收藏/分享
文件名: A Potentiometric Flow Biosensor Based on Ammonia-Oxidizing Bacteria for the Detection of Toxicity in Water.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。