Polycation-sensitive membrane electrode for determination of heparin based on controlled release of protamine | |
Chen, Yan1,2; Ding, Jiawang1; Qin, Wei1 | |
发表期刊 | ANALYST |
2012 | |
卷号 | 137期号:8页码:1944-1949 |
关键词 | Potentiometric Polyanion Sensors Bioanalytical Applications Electrochemical Sensor Selective Electrodes Response Mechanism Polyion Contaminants Binding Assay |
产权排序 | [Chen, Yan; Ding, Jiawang; Qin, Wei] CAS, Key Lab Coastal Zone Environm Proc, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai Inst Coastal Zone Res YIC,YICCAS, Yantai 264003, Shandong, Peoples R China; [Chen, Yan] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China |
英文摘要 | A polycation-selective polymeric membrane electrode using dinonylnaphthalene sulfonate as an ion exchanger has been developed as a protamine controlled-release system for potentiometric detection of heparin. The incorporation of tetradodecylammonium tetrakis(4-chlorophenyl)borate as a lipophilic salt in the membrane dramatically improves the sensor's selectivity towards protamine over sodium ions via influencing the activity coefficient of protamine in the membrane, and a stable potential baseline can be obtained in the presence of an electrolyte background. The electrostatic binding interaction between heparin and protamine decreases the concentration of free protamine released at the sample-membrane interface and facilitates the stripping of protamine out of the membrane surface via the ion-exchange process with sodium ions, thus decreasing the membrane potential. Under optimal conditions, the proposed polymeric membrane electrode exhibits a linear relationship between the initial slope of the potential change and the heparin concentration in the range of 0.025-1.25 U mL(-1) with an improved detection limit of 0.01 U mL(-1).; A polycation-selective polymeric membrane electrode using dinonylnaphthalene sulfonate as an ion exchanger has been developed as a protamine controlled-release system for potentiometric detection of heparin. The incorporation of tetradodecylammonium tetrakis(4-chlorophenyl)borate as a lipophilic salt in the membrane dramatically improves the sensor's selectivity towards protamine over sodium ions via influencing the activity coefficient of protamine in the membrane, and a stable potential baseline can be obtained in the presence of an electrolyte background. The electrostatic binding interaction between heparin and protamine decreases the concentration of free protamine released at the sample-membrane interface and facilitates the stripping of protamine out of the membrane surface via the ion-exchange process with sodium ions, thus decreasing the membrane potential. Under optimal conditions, the proposed polymeric membrane electrode exhibits a linear relationship between the initial slope of the potential change and the heparin concentration in the range of 0.025-1.25 U mL(-1) with an improved detection limit of 0.01 U mL(-1). |
文章类型 | Article |
资助机构 | National Natural Science Foundation of China[41176081]; Outstanding Youth Natural Science Foundation of Shandong Province[JQ200814]; Taishan Scholar Program of Shandong Province[TS20081159] |
收录类别 | SCI |
语种 | 英语 |
关键词[WOS] | POTENTIOMETRIC POLYANION SENSORS ; BIOANALYTICAL APPLICATIONS ; ELECTROCHEMICAL SENSOR ; SELECTIVE ELECTRODES ; RESPONSE MECHANISM ; POLYION ; CONTAMINANTS ; BINDING ; ASSAY |
研究领域[WOS] | Chemistry |
WOS记录号 | WOS:000301674600030 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.yic.ac.cn/handle/133337/5412 |
专题 | 中国科学院海岸带环境过程与生态修复重点实验室_海岸带环境过程实验室 |
作者单位 | 1.CAS, Key Lab Coastal Zone Environm Proc, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai Inst Coastal Zone Res YIC,YICCAS, Yantai 264003, Shandong, Peoples R China 2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Chen, Yan,Ding, Jiawang,Qin, Wei. Polycation-sensitive membrane electrode for determination of heparin based on controlled release of protamine[J]. ANALYST,2012,137(8):1944-1949. |
APA | Chen, Yan,Ding, Jiawang,&Qin, Wei.(2012).Polycation-sensitive membrane electrode for determination of heparin based on controlled release of protamine.ANALYST,137(8),1944-1949. |
MLA | Chen, Yan,et al."Polycation-sensitive membrane electrode for determination of heparin based on controlled release of protamine".ANALYST 137.8(2012):1944-1949. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Polycation-sensitive(333KB) | 开放获取 | 使用许可 | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论