Tetra(p-tolyl)borate-Functionalized Solvent Polymeric Membrane: A Facile and Sensitive Sensing Platform for Peroxidase and Peroxidase Mimetics | |
Wang, Xuewei1,2; Qin, Wei1 | |
发表期刊 | CHEMISTRY-A EUROPEAN JOURNAL |
ISSN | 0947-6539 |
2013-07-22 | |
卷号 | 19期号:30页码:9979-9986 |
关键词 | Biosensors Intermediate-sensitive Membranes Peroxidase Peroxidase Mimetics Potentiometry |
产权排序 | [Wang, Xuewei; Qin, Wei] Chinese Acad Sci, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Yantai Inst Coastal Zone Res YIC, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai 264003, Shandong, Peoples R China; [Wang, Xuewei] Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
通讯作者 | Qin, W (reprint author), Chinese Acad Sci, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Yantai Inst Coastal Zone Res YIC, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai 264003, Shandong, Peoples R China. wqin@yic.ac.cn |
英文摘要 | The determination of peroxidase activities is the basis for enzyme-labeled bioaffinity assays, peroxidase-mimicking DNAzymes- and nanoparticles-based assays, and characterization of the catalytic functions of peroxidase mimetics. Here, a facile, sensitive, and cost-effective solvent polymeric membrane-based peroxidase detection platform is described that utilizes reaction intermediates with different pK(a) values from those of substrates and final products. Several key but long-debated intermediates in the peroxidative oxidation of o-phenylenediamine (o-PD) have been identified and their charge states have been estimated. By using a solvent polymeric membrane functionalized by an appropriate substituted tetraphenylborate as a receptor, those cationic intermediates could be transferred into the membrane from the aqueous phase to induce a large cationic potential response. Thus, the potentiometric indication of the o-PD oxidation catalyzed by peroxidase or its mimetics can be fulfilled. Horseradish peroxidase has been detected with a detection limit at least two orders of magnitude lower than those obtained by spectrophotometric techniques and traditional membrane-based methods. As an example of peroxidase mimetics, G-quadruplex DNAzymes were probed by the intermediate-sensitive membrane and a label-free thrombin detection protocol was developed based on the catalytic activity of the thrombin-binding G-quadruplex aptamer.; The determination of peroxidase activities is the basis for enzyme-labeled bioaffinity assays, peroxidase-mimicking DNAzymes- and nanoparticles-based assays, and characterization of the catalytic functions of peroxidase mimetics. Here, a facile, sensitive, and cost-effective solvent polymeric membrane-based peroxidase detection platform is described that utilizes reaction intermediates with different pK(a) values from those of substrates and final products. Several key but long-debated intermediates in the peroxidative oxidation of o-phenylenediamine (o-PD) have been identified and their charge states have been estimated. By using a solvent polymeric membrane functionalized by an appropriate substituted tetraphenylborate as a receptor, those cationic intermediates could be transferred into the membrane from the aqueous phase to induce a large cationic potential response. Thus, the potentiometric indication of the o-PD oxidation catalyzed by peroxidase or its mimetics can be fulfilled. Horseradish peroxidase has been detected with a detection limit at least two orders of magnitude lower than those obtained by spectrophotometric techniques and traditional membrane-based methods. As an example of peroxidase mimetics, G-quadruplex DNAzymes were probed by the intermediate-sensitive membrane and a label-free thrombin detection protocol was developed based on the catalytic activity of the thrombin-binding G-quadruplex aptamer. |
文章类型 | Article |
资助机构 | Instrument Developing Project of the Chinese Academy of Sciences [YZ201161]; National Natural Science Foundation of China [41176081]; Taishan Scholar Program of Shandong Province [TS20081159] |
收录类别 | SCI |
语种 | 英语 |
关键词[WOS] | QUADRUPLEX-BASED DNAZYME ; ION-SELECTIVE ELECTRODE ; BENZOQUINONE DI-IMINES ; HORSERADISH-PEROXIDASE ; O-PHENYLENEDIAMINE ; COLORIMETRIC DETECTION ; ELECTROCHEMICAL ASSAY ; CATALYZED OXIDATION ; ENZYME-IMMUNOASSAY ; HYDROGEN-PEROXIDE |
研究领域[WOS] | Chemistry |
WOS记录号 | WOS:000321766400036 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.yic.ac.cn/handle/133337/6973 |
专题 | 中国科学院海岸带环境过程与生态修复重点实验室 |
作者单位 | 1.Chinese Acad Sci, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Yantai Inst Coastal Zone Res YIC, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai 264003, Shandong, Peoples R China 2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Wang, Xuewei,Qin, Wei. Tetra(p-tolyl)borate-Functionalized Solvent Polymeric Membrane: A Facile and Sensitive Sensing Platform for Peroxidase and Peroxidase Mimetics[J]. CHEMISTRY-A EUROPEAN JOURNAL,2013,19(30):9979-9986. |
APA | Wang, Xuewei,&Qin, Wei.(2013).Tetra(p-tolyl)borate-Functionalized Solvent Polymeric Membrane: A Facile and Sensitive Sensing Platform for Peroxidase and Peroxidase Mimetics.CHEMISTRY-A EUROPEAN JOURNAL,19(30),9979-9986. |
MLA | Wang, Xuewei,et al."Tetra(p-tolyl)borate-Functionalized Solvent Polymeric Membrane: A Facile and Sensitive Sensing Platform for Peroxidase and Peroxidase Mimetics".CHEMISTRY-A EUROPEAN JOURNAL 19.30(2013):9979-9986. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Tetra(p-tolyl)borate(334KB) | 开放获取 | CC BY-NC-SA | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Wang, Xuewei]的文章 |
[Qin, Wei]的文章 |
百度学术 |
百度学术中相似的文章 |
[Wang, Xuewei]的文章 |
[Qin, Wei]的文章 |
必应学术 |
必应学术中相似的文章 |
[Wang, Xuewei]的文章 |
[Qin, Wei]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论