Mercury(II) ion sensing with PVC-matrix based membrane sensors | |
Rakesh Kumar Mahajan ; Kaur Ravneet ; Lobana Tarlok S. | |
发表期刊 | Indian Journal of Chemistry Section A Inorganic Physical Theoretical Analytical |
ISSN | 0376-4710 |
2006 | |
卷号 | 45期号:3页码:639-642 |
通讯作者 | Rakesh Kumar Mahajan |
英文摘要 | Thiosemicarbazone derivatives have been used as ion carriers for the preparation of PVC-matrix based mercury(II)-selective membrane sensors. The electrodes give near-Nernstian responses in the linear concentration range of 1.0×10-1-5.0×10-6 M with detection limits of the order of 10-6 M. The stable potentiometric signals are obtained within a short time period of 20-25s. The effect of different plasticizers has been studied and dioctylsebacate (DOS) found to give a better response in comparison to other plasticizers. Selectivity coefficient values (log KPotHg,M) have been evaluated using fixed interference method. Better selectivity for mercury(II) ions is observed over many of the monovalent (Na+, K+ and NH4+) and divalent ions (Mg2+, Ca2+, Zn2+, Pb2+, Ni2+, Co2+, etc.). The sensors have also been used as indicator electrodes in potentiometric titration of mercury(II) ions with EDTA and its determination in synthetic water samples. |
语种 | 英语 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.yic.ac.cn/handle/133337/3127 |
专题 | 科研共享资源 |
推荐引用方式 GB/T 7714 | Rakesh Kumar Mahajan,Kaur Ravneet,Lobana Tarlok S.. Mercury(II) ion sensing with PVC-matrix based membrane sensors[J]. Indian Journal of Chemistry Section A Inorganic Physical Theoretical Analytical,2006,45(3):639-642. |
APA | Rakesh Kumar Mahajan,Kaur Ravneet,&Lobana Tarlok S..(2006).Mercury(II) ion sensing with PVC-matrix based membrane sensors.Indian Journal of Chemistry Section A Inorganic Physical Theoretical Analytical,45(3),639-642. |
MLA | Rakesh Kumar Mahajan,et al."Mercury(II) ion sensing with PVC-matrix based membrane sensors".Indian Journal of Chemistry Section A Inorganic Physical Theoretical Analytical 45.3(2006):639-642. |