YIC-IR  > 科研共享资源
Flow-through room temperature phosphorescence optosensing for the determination of lead in sea water
Blanca San Vicente de la Riva ; Jose Manuel Costa-FernaÂndez ; Rosario Pereiro ; Alfredo Sanz-Medel
发表期刊Analytica Chimica Acta
ISSN0003-2670
1999
页码1--9
关键词Flow-through Optosensing Room Temperature Phosphorescence Lead Sea Water
英文摘要The chelates formed between the heavy metal ion Pb(II) and the reagents 8-hydroxy-5-quinolinesulphonic acid, 8-hydroxy-7-quinolinesulphonic acid and 8-hydroxy-7-iodo-5-quinolinesulphonic acid exhibit strong room temperature phosphorescence (RTP) if retained on the surface of anion exchange resin beads. Based on the on-line formation, in a flow-injection system, of such RTP lead chelates and their transient immobilization on an anion exchange resin, three flow-through optosensing systems are investigated for lead in sea water. Optimum experimental conditions and the analytical performance characteristics of the three optosensors are discussed. Relative standard deviations (RSDs) of the order of 3% are typical at 100 ng ml−1 Pb(II) and the active sensing phases can easily be regenerated by passing 500 μl of 6 M hydrochloric acid. A lead(II) detection limit of 0.1 ng ml−1 (3×background SD, for 2 ml sample injection volumes) was achieved for the optosensor based on 8-hydroxy-7-quinolinesulphonic acid. Possible interferences present in sea water, including cations and anions which could affect the sensor response, are discussed in detail. Finally, the selected RTP flow-through optical sensor has been successfully tested for the determination of lead in sea water at a few ng ml−1.
语种英语
文献类型期刊论文
条目标识符http://ir.yic.ac.cn/handle/133337/2993
专题科研共享资源
推荐引用方式
GB/T 7714
Blanca San Vicente de la Riva,Jose Manuel Costa-FernaÂndez,Rosario Pereiro,et al. Flow-through room temperature phosphorescence optosensing for the determination of lead in sea water[J]. Analytica Chimica Acta,1999:1--9.
APA Blanca San Vicente de la Riva,Jose Manuel Costa-FernaÂndez,Rosario Pereiro,&Alfredo Sanz-Medel.(1999).Flow-through room temperature phosphorescence optosensing for the determination of lead in sea water.Analytica Chimica Acta,1--9.
MLA Blanca San Vicente de la Riva,et al."Flow-through room temperature phosphorescence optosensing for the determination of lead in sea water".Analytica Chimica Acta (1999):1--9.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Flow-through room te(224KB) 限制开放--请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Blanca San Vicente de la Riva]的文章
[Jose Manuel Costa-FernaÂndez]的文章
[Rosario Pereiro]的文章
百度学术
百度学术中相似的文章
[Blanca San Vicente de la Riva]的文章
[Jose Manuel Costa-FernaÂndez]的文章
[Rosario Pereiro]的文章
必应学术
必应学术中相似的文章
[Blanca San Vicente de la Riva]的文章
[Jose Manuel Costa-FernaÂndez]的文章
[Rosario Pereiro]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。