An all-solid-state polymeric membrane Pb2+-selective electrode with bimodal pore C-60 as solid contact
Li, Jinghui; Yin, Tanji; Qin, Wei; Qin, W (reprint author), Chinese Acad Sci, Shandong Prov Key Lab Coastal Environm Proc, Key Lab Coastal Environm Proc & Ecol Remediat, Yantai Inst Coastal Zone Res YIC,YICCAS, Yantai 264003, Shandong, Peoples R China. wqin@yic.ac.cn
发表期刊ANALYTICA CHIMICA ACTA
ISSN0003-2670
2015-05-30
卷号876页码:49-54
关键词Solid Contact Bimodal Pore C-60 All Solid State Ion-selective Electrode Electrodeposition Lead
DOI10.1016/j.aca.2015.03.038
产权排序[Li, Jinghui; Yin, Tanji; Qin, Wei] Chinese Acad Sci, Shandong Prov Key Lab Coastal Environm Proc, Key Lab Coastal Environm Proc & Ecol Remediat, Yantai Inst Coastal Zone Res YIC,YICCAS, Yantai 264003, Shandong, Peoples R China; [Li, Jinghui] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
作者部门中科院海岸带环境过程与生态修复重点实验室
英文摘要An all-solid-state polymeric membrane Pb2+ ion-selective electrode (Pb2+-ISE) based on bimodal pore C-60 (BP-C-60) as solid contact has been developed. A BP-C-60 film can be readily formed on the surface of a glassy carbon electrode by electrochemical deposition. Cyclic voltammetry and electrochemical impedance spectroscopy have been employed to characterize the BP-C-60 film. The large double layer capacitance and fast charge-transfer capability make BP-C-60 favorable to be used as solid contact for developing all-solid-state ISEs. The all-solid-state BP-C-60-based Pb2+-ISE shows a Nernstian response in the range from 1.0 x 10 (9) to 1.0 x 10 (3) M with a detection limit of 5.0 x 10 (10) M. The membrane electrode not only displays an excellent potential stability with the absence of a water layer between the ion-selective membrane and the underlying BP-C-60 solid contact, but also is insensitive to interferences from O-2, CO2 and light. The proposed solid-contact Pb2+-ISE has been applied to determine Pb2+ in real water samples and the results agree well with those obtained by anodic stripping voltammetry. (C) 2015 Elsevier B.V. All rights reserved.; An all-solid-state polymeric membrane Pb2+ ion-selective electrode (Pb2+-ISE) based on bimodal pore C-60 (BP-C-60) as solid contact has been developed. A BP-C-60 film can be readily formed on the surface of a glassy carbon electrode by electrochemical deposition. Cyclic voltammetry and electrochemical impedance spectroscopy have been employed to characterize the BP-C-60 film. The large double layer capacitance and fast charge-transfer capability make BP-C-60 favorable to be used as solid contact for developing all-solid-state ISEs. The all-solid-state BP-C-60-based Pb2+-ISE shows a Nernstian response in the range from 1.0 x 10 (9) to 1.0 x 10 (3) M with a detection limit of 5.0 x 10 (10) M. The membrane electrode not only displays an excellent potential stability with the absence of a water layer between the ion-selective membrane and the underlying BP-C-60 solid contact, but also is insensitive to interferences from O-2, CO2 and light. The proposed solid-contact Pb2+-ISE has been applied to determine Pb2+ in real water samples and the results agree well with those obtained by anodic stripping voltammetry. (C) 2015 Elsevier B.V. All rights reserved.
文章类型Article
资助机构Chemistry
收录类别SCI
语种英语
关键词[WOS]ION-SELECTIVE ELECTRODES ; REDUCED GRAPHENE OXIDE ; DETECTION LIMIT ; CARBON ; SENSORS ; FILMS ; TRANSDUCERS ; STABILITY ; COMPLEXES
研究领域[WOS]Chemistry
WOS记录号WOS:000354780400005
引用统计
被引频次:45[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.yic.ac.cn/handle/133337/8609
专题中国科学院海岸带环境过程与生态修复重点实验室
中国科学院海岸带环境过程与生态修复重点实验室_海岸带环境过程实验室
通讯作者Qin, W (reprint author), Chinese Acad Sci, Shandong Prov Key Lab Coastal Environm Proc, Key Lab Coastal Environm Proc & Ecol Remediat, Yantai Inst Coastal Zone Res YIC,YICCAS, Yantai 264003, Shandong, Peoples R China. wqin@yic.ac.cn
推荐引用方式
GB/T 7714
Li, Jinghui,Yin, Tanji,Qin, Wei,et al. An all-solid-state polymeric membrane Pb2+-selective electrode with bimodal pore C-60 as solid contact[J]. ANALYTICA CHIMICA ACTA,2015,876:49-54.
APA Li, Jinghui,Yin, Tanji,Qin, Wei,&Qin, W .(2015).An all-solid-state polymeric membrane Pb2+-selective electrode with bimodal pore C-60 as solid contact.ANALYTICA CHIMICA ACTA,876,49-54.
MLA Li, Jinghui,et al."An all-solid-state polymeric membrane Pb2+-selective electrode with bimodal pore C-60 as solid contact".ANALYTICA CHIMICA ACTA 876(2015):49-54.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
An all-solid-state p(709KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Li, Jinghui]的文章
[Yin, Tanji]的文章
[Qin, Wei]的文章
百度学术
百度学术中相似的文章
[Li, Jinghui]的文章
[Yin, Tanji]的文章
[Qin, Wei]的文章
必应学术
必应学术中相似的文章
[Li, Jinghui]的文章
[Yin, Tanji]的文章
[Qin, Wei]的文章
相关权益政策
暂无数据
收藏/分享
文件名: An all-solid-state polymeric membrane Pb2+-selective electrode with bimodal pore C60 as solid contact.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。