An ionophore-Nafion modified bismuth electrode for the analysis of cadmium(II)
Jiang, Lin1,2,3; Wang, Yuane1,2,3; Ding, Jiawang1,3; Lou, Tingting1,2,3; Qin, Wei1,4
发表期刊ELECTROCHEMISTRY COMMUNICATIONS
2010-02-01
卷号12期号:2页码:202-205
关键词Ionophore Nafion Bismuth Electrode Cadmium Stripping Voltammetry
产权排序[Jiang, Lin; Wang, Yuane; Ding, Jiawang; Lou, Tingting; Qin, Wei] Chinese Acad Sci, Yantai Inst Coastal Zone Res, Key Lab Coastal Environm Proc, Yantai 264003, Peoples R China; [Jiang, Lin; Wang, Yuane; Lou, Tingting] Chinese Acad Sci, Inst Oceanol, Qingdao 266071, Peoples R China; [Jiang, Lin; Wang, Yuane; Ding, Jiawang; Lou, Tingting] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China; [Qin, Wei] Yantai Univ, Sch Oceanol, Yantai 264005, Peoples R China
通讯作者Qin, W, Chinese Acad Sci, Yantai Inst Coastal Zone Res, Key Lab Coastal Environm Proc, Yantai 264003, Peoples R China
作者部门环境化学实验室 
英文摘要A novel ionophore-Nafion modified bismuth electrode is described for sensitive and selective anodic stripping analysis of cadmium(II). The electrode is prepared by coating the glassy carbon electrode with the cadmium ionophore N,N,N',N'-tetrabutyl-3,6-dioxaoctanedi(thioamide) and Nafion composite. Bismuth is deposited in situ on the electrode surface by plating simultaneously with cadmium in sample solution. Numerous key variables affecting the current response of cadmium have been optimized. The electrode has a linear concentration range of 0.5-10 nM with a deposition time of 180 s. The detection limit is 1.3 x 10(-10) M and the relative standard deviations for 0.5 and 7 nM cadmium are 6.5% and 4.5%, respectively. The proposed electrode shows excellent selectivity over other heavy metals, such as copper, lead and indium. The attractive performance of such electrode offers a feasible way to monitor trace cadmium(II) rapidly and precisely in complex matrixes. (C) 2009 Elsevier B.V. All rights reserved.; A novel ionophore-Nafion modified bismuth electrode is described for sensitive and selective anodic stripping analysis of cadmium(II). The electrode is prepared by coating the glassy carbon electrode with the cadmium ionophore N,N,N',N'-tetrabutyl-3,6-dioxaoctanedi(thioamide) and Nafion composite. Bismuth is deposited in situ on the electrode surface by plating simultaneously with cadmium in sample solution. Numerous key variables affecting the current response of cadmium have been optimized. The electrode has a linear concentration range of 0.5-10 nM with a deposition time of 180 s. The detection limit is 1.3 x 10(-10) M and the relative standard deviations for 0.5 and 7 nM cadmium are 6.5% and 4.5%, respectively. The proposed electrode shows excellent selectivity over other heavy metals, such as copper, lead and indium. The attractive performance of such electrode offers a feasible way to monitor trace cadmium(II) rapidly and precisely in complex matrixes. (C) 2009 Elsevier B.V. All rights reserved.
文章类型Article
资助机构Chinese Academy of Sciences [KZCX2-YW-410]; National Natural Science Foundation of China [40776058]; National 863 High Technology Project of the Ministry of Science and Technology of China [2007AA09Z103]; Scientific Research Foundation ; Department of Science and Technology of Shandong Province [2006GG2205033]; Outstanding Youth Natural Science Foundation of Shandong Province [JQ200814]; Taishan Scholar Program of Shandong Province
收录类别SCI
语种英语
关键词[WOS]ANODIC-STRIPPING VOLTAMMETRY ; FILM ELECTRODES ; CARBON ELECTRODES ; TRACE-METALS ; LEAD ; MEMBRANE
研究领域[WOS]Electrochemistry
WOS记录号WOS:000274878400007
引用统计
被引频次:35[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.yic.ac.cn/handle/133337/3707
专题中国科学院海岸带环境过程与生态修复重点实验室_海岸带环境过程实验室
作者单位1.Chinese Acad Sci, Yantai Inst Coastal Zone Res, Key Lab Coastal Environm Proc, Yantai 264003, Peoples R China
2.Chinese Acad Sci, Inst Oceanol, Qingdao 266071, Peoples R China
3.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
4.Yantai Univ, Sch Oceanol, Yantai 264005, Peoples R China
推荐引用方式
GB/T 7714
Jiang, Lin,Wang, Yuane,Ding, Jiawang,et al. An ionophore-Nafion modified bismuth electrode for the analysis of cadmium(II)[J]. ELECTROCHEMISTRY COMMUNICATIONS,2010,12(2):202-205.
APA Jiang, Lin,Wang, Yuane,Ding, Jiawang,Lou, Tingting,&Qin, Wei.(2010).An ionophore-Nafion modified bismuth electrode for the analysis of cadmium(II).ELECTROCHEMISTRY COMMUNICATIONS,12(2),202-205.
MLA Jiang, Lin,et al."An ionophore-Nafion modified bismuth electrode for the analysis of cadmium(II)".ELECTROCHEMISTRY COMMUNICATIONS 12.2(2010):202-205.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
An ionophore–Nafion (239KB) 开放获取--浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Jiang, Lin]的文章
[Wang, Yuane]的文章
[Ding, Jiawang]的文章
百度学术
百度学术中相似的文章
[Jiang, Lin]的文章
[Wang, Yuane]的文章
[Ding, Jiawang]的文章
必应学术
必应学术中相似的文章
[Jiang, Lin]的文章
[Wang, Yuane]的文章
[Ding, Jiawang]的文章
相关权益政策
暂无数据
收藏/分享
文件名: An ionophore–Nafion modified bismuth electrode for the analysis of cadmium(II).pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。