Improving the Biocompatibility of Polymeric Membrane Potentiometric Ion Sensors by Using a Mussel-Inspired Polydopamine Coating
Jiang, XJ; Wang, P; Liang, RN; Qin, W
发表期刊ANALYTICAL CHEMISTRY
ISSN0003-2700
2019-05-21
卷号91期号:10页码:6424-6429
关键词SELECTIVE ELECTRODES BLOOD COMPATIBILITY PHOSPHORYLCHOLINE SURFACES
研究领域Chemistry, Analytical
DOI10.1021/acs.analchem.9b00039
产权排序[Jiang, Xiaojing; Liang, Rongning; Qin, Wei] Chinese Acad Sci, Yantai Inst Coastal Zone Res, CAS Key Lab Coastal Environm Proc & Ecol Remediat, Yantai 264003, Shandong, Peoples R China; [Jiang, Xiaojing; Liang, Rongning; Qin, Wei] Chinese Acad Sci, Yantai Inst Coastal Zone Res, Shandong Key Lab Coastal Environm Proc, Yantai 264003, Shandong, Peoples R China; [Liang, Rongning; Qin, Wei] Qingdao Natl Lab Marine Sci & Technol, Lab Marine Biol & Biotechnol, Qingdao 266200, Shandong, Peoples R China; [Jiang, Xiaojing] Univ Chinese Acad Sci, Beijing 100049, Peoples R China; [Wang, Peng] Shandong B&E Biotechnol Co Ltd, Yantai, Peoples R China
通讯作者Liang, Rongning(rnliang@yic.ac.cn) ; Qin, Wei(wqin@yic.ac.cn)
作者部门海岸带环境过程实验室
英文摘要Polymeric membrane potentiometric ion sensors have been widely used in clinical diagnosis for the detection of electrolyte ions and account for billions of measurements every year throughout the world. However, in many cases of practical relevance, biofouling, which might lead to sensor failure, usually occurs due to the lack of biocompatibility of these sensors. Herein, we describe a simple and robust approach for improving the biocompatibility of the polymeric ion-selective membranes. A marine mussel-inspired polydopamine polymer is used as a hydrophilic coating on the surface of conventional potentiometric ion sensors. Such a coating can be easily formed by self-polymerization of dopamine and robustly deposited on the sensor surface mimicking the adhesion mechanism of mussels. The classical poly(vinyl chloride) membrane-based calcium ion-selective electrode (ISE) is chosen as a model. Compared to the unmodified Ca2+ ISE, the polydopamine modified electrode shows a significantly reduced blood platelet adsorption while retaining original potentiometric ion response properties, which clearly indicates a high antifouling capability induced by the hydrophilic polydopamine coating. We believe that the proposed approach can provide an appealing way to improve the biocompatibility in the development of polymeric membrane electrochemical and optical sensors.
文章类型Article
资助机构National Natural Science Foundation of ChinaNational Natural Science Foundation of China [21874151, 21677172, 41576106] ; National Key Research and Development Program of China [2016YFC1400700] ; Youth Innovation Promotion Association of CAS [2014190] ; Taishan Scholar Program of Shandong Province [tspd20181215]
收录类别SCI
语种英语
关键词[WOS]SELECTIVE ELECTRODES ; BLOOD COMPATIBILITY ; PHOSPHORYLCHOLINE ; SURFACES
研究领域[WOS]Chemistry, Analytical
WOS记录号WOS:000469304300006
引用统计
被引频次:32[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.yic.ac.cn/handle/133337/24937
专题中国科学院海岸带环境过程与生态修复重点实验室_海岸带环境过程实验室
中国科学院海岸带环境过程与生态修复重点实验室
作者单位1.Chinese Acad Sci, Yantai Inst Coastal Zone Res, CAS Key Lab Coastal Environm Proc & Ecol Remediat, Yantai 264003, Shandong, Peoples R China;
2.Chinese Acad Sci, Yantai Inst Coastal Zone Res, Shandong Key Lab Coastal Environm Proc, Yantai 264003, Shandong, Peoples R China;
3.Qingdao Natl Lab Marine Sci & Technol, Lab Marine Biol & Biotechnol, Qingdao 266200, Shandong, Peoples R China;
4.Univ Chinese Acad Sci, Beijing 100049, Peoples R China;
5.Shandong B&E Biotechnol Co Ltd, Yantai, Peoples R China
推荐引用方式
GB/T 7714
Jiang, XJ,Wang, P,Liang, RN,et al. Improving the Biocompatibility of Polymeric Membrane Potentiometric Ion Sensors by Using a Mussel-Inspired Polydopamine Coating[J]. ANALYTICAL CHEMISTRY,2019,91(10):6424-6429.
APA Jiang, XJ,Wang, P,Liang, RN,&Qin, W.(2019).Improving the Biocompatibility of Polymeric Membrane Potentiometric Ion Sensors by Using a Mussel-Inspired Polydopamine Coating.ANALYTICAL CHEMISTRY,91(10),6424-6429.
MLA Jiang, XJ,et al."Improving the Biocompatibility of Polymeric Membrane Potentiometric Ion Sensors by Using a Mussel-Inspired Polydopamine Coating".ANALYTICAL CHEMISTRY 91.10(2019):6424-6429.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Improving the Biocom(2873KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Jiang, XJ]的文章
[Wang, P]的文章
[Liang, RN]的文章
百度学术
百度学术中相似的文章
[Jiang, XJ]的文章
[Wang, P]的文章
[Liang, RN]的文章
必应学术
必应学术中相似的文章
[Jiang, XJ]的文章
[Wang, P]的文章
[Liang, RN]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Improving the Biocompatibility of Polymeric Membrane Potentiometric Ion Sensors by Using a Mussel-Inspired Polydopamine Coating.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。